MV Terminal (6.6kV1)

Abtech's medium voltage terminal is a component-certified device that simplifies the connection of 4.4 to 6.6kV electrical supplies. It can be used with any ATEX or IECEx Zone 1 certified enclosure.

Enclosure Ratings

Depth

Y

(MM)

Maximum Voltage (kV)

Maximum Current (A)

Maximum Conductor Size (mm2)

Maximum Ways

Weight (kg)

Standard Specifications

Product Type

Material

Operating Temp Rating

Crimps Lungs

Mounting

Certification

Area Classification

Type of Protection

Apparatus Coding

 Certificate Number

Medium Voltage Terminal

Plastic UTR Laminate GPO3 grade 1494

-40oc to + 130oC

M8 single hole sizes 1.5mm2 up to 240mm2

4 x M8 clearance holes

Enter your text here

 Zone 1 & 21, Gas and Dust / Class 1 Div 2

Ex e (Increased Safety)

Ex e IIC Gb

CML 15ATEX3096U / IECEx: CML 15.0051U

  • • Available in three, four, and six-way configurations.
  • Can be linked in pairs or multiples.
  • Suitable for high ambient temperature applications.

TATEMV3

168

153

220

200

102

4.4

250

240

3

1.8

TATEMV4

212

197

220

200

102

4.4

250

240

4

2.4

TATEMV6

300

285

220

200

102

4.4

250

240

6

3.7

TATEMV3T

168

153

220

200

114

6.6

250

240

3

1.8

TATEMV4T

212

197

220

200

114

6.6

250

240

4

2.4

TATEMV6T

300

285

220

200

114

6.6

250

240

6

3.7

General Arrangement

Options

Lxx

 

 

Linking:

1St x = link type (pairs, triple)

2nd x Quantity of links required

Add the required suffix to the product reference. Example: TATEMV6TL23 — 6 way 6.6kV max terminal block linked in pairs, three links.

High Voltage

IP66 to EN60529, Type 4X, DTS-01

>7Nm

2mm 316L Stainless Steel (EN 1.4404) enclosure with orbital finish, silicone gasket and captive 316 stainless steel fasteners, 3mm 316L (EN 1.4404) Stainless Steel gland plates

 -20°C to +40°C or -50°C to +55°C (refer to certificate)

3 conductors per phase in & 3 conductors per phase out

Dependant upon configuration

16mm2 to 1000mm2

Via studs on enclosure, door and gland plates

Via 3mm thick external mounting straps, slotted upper strap for ease of installation Certification

Enter your text here

 Zone 1 & 21, Gas and Dust / Class 1 Div 2

Ex eb (Increased Safety), Ex tb (Dust Protected)

Ex eb IIC T4 Gb, Ex tb IIIC T70°C Db / Ex eb IIC T150°C Gb, Ex tb IIIC T110°C Db

CML 16ATEX3324 & IECEx CML16.0100 / EAC: TC RU C-GB.MH04.B.00286

*dependant on conductor size and lug configuration

 Width

(MM)

Height

(MM)

Product Reference

 

 

 

X

X(M)

Y

Y(M)

Depth

Y

(MM)

Maximum Voltage (kV)

Maximum Current (A)

Maximum Conductor Size (mm2)

Maximum Ways

Weight (kg)

TATEMV3

168

153

220

200

102

4.4

250

240

3

1.8

TATEMV4

212

197

220

200

102

4.4

250

240

4

2.4

TATEMV6

300

285

220

200

102

4.4

250

240

6

3.7

TATEMV3T

168

153

220

200

114

6.6

250

240

3

1.8

TATEMV4T

212

197

220

200

114

6.6

250

240

4

2.4

TATEMV6T

300

285

220

200

114

6.6

250

240

6

3.7

Product Type

Material

Operating Temp Rating

Crimps Lungs

Mounting

Certification

Area Classification

Type of Protection

Apparatus Coding

 Certificate Number

Medium Voltage Terminal

Plastic UTR Laminate GPO3 grade 1494

-40oc to + 130oC

M8 single hole sizes 1.5mm2 up to 240mm2

4 x M8 clearance holes

Enter your text here

 Zone 1 & 21, Gas and Dust / Class 1 Div 2

Ex e (Increased Safety)

Ex e IIC Gb

CML 15ATEX3096U / IECEx: CML 15.0051U