The latest in the high voltage range offering enhanced flexibility over the choice of cables, entries, and cable terminations. The HVJB can accept up to 4 phase connections either straight-through or bottom entry only. The unit can accommodate up to three connectors per phase.
Enclosure Ratings
Product Reference* | Width (mm) | Height (MM) | Depth (MM) | Maximum Power Rating @ T4 (W)** | Maximum Voltage (kV) | Maximum Current (A) | Maximum Conductor Size (mm2) | Maximum Ways | Weight (kg) |
Standard Specifications
Enclosure Type |
Ingress Protection |
Impact Resistance |
Material
|
Ambient Temp Rating |
Maximum Terminations |
No. of Gland Plates |
Crimp lugs |
Earthing |
Mounting
|
Certification |
Area Classification |
Type of Protection |
Apparatus Coding |
Certificate Number |
High Voltage |
IP66 to EN60529, Type 4X, DTS-01 |
>7Nm |
2mm 316L Stainless Steel (EN 1.4404) enclosure with orbital finish, silicone gasket and captive 316 stainless steel fasteners, 3mm 316L (EN 1.4404) Stainless Steel gland plates |
-20°C to +40°C or -50°C to +55°C (refer to certificate) |
3 conductors per phase in & 3 conductors per phase out |
Dependant upon configuration |
16mm2 to 1000mm2 |
Via studs on enclosure, door and gland plates |
Via 3mm thick external mounting straps, slotted upper strap for ease of installation Certification |
Enter your text here |
Zone 1 & 21, Gas and Dust / Class 1 Div 2 |
Ex eb (Increased Safety), Ex tb (Dust Protected) |
Ex eb IIC T4 Gb, Ex tb IIIC T70°C Db / Ex eb IIC T150°C Gb, Ex tb IIIC T110°C Db |
CML 16ATEX3324 & IECEx CML16.0100 / EAC: TC RU C-GB.MH04.B.00286 |
X | X(M) | Y | Y(M) | Z |
HVJB73(x-x) | 650 | 950 | 300 | 259/129.5 | 11 | 980 | 1000 | 3 | 70 |
HVJB83(x-x) | 800 | 1250 | 300 | 346/173 | 11 | 980 | 1000 | 3 | 97 |
HVJB84(x-x) | 800 | 1250 | 300 | 346/173 | 11 | 980 | 1000 | 4 | 97 |
General Arrangement
HVJB73 |
HVJB83 |
HVJB84 |
650 | 700 | 950 | 750 | 300 |
800 | 850 | 1250 | 1050 | 300 |
800 | 850 | 1250 | 1050 | 300 |
Dimensions in mm
Options
ACH |
EP |
RALxxxx |
BPG |
MB |
Anti-condensation heater (dependent upon available internal dimensions) |
Electro-polished |
Epoxy powder coated, (RAL colour may be specified) |
BPG Control cores terminal box mounted internally |
Mounting boss for eye bolts |
Add the required suffix to the product reference. Example: HVJB73(0-3)BPG = HVJB 7, 3- way with 3 entries in bottom and internal terminal box.
Accessories
ABDM2010SS |
ABDM2510SS |
FBM12EEMS*** |
FBM16EEMS*** |
M20 Breather drain |
M25 Breather drain |
M12 Lifting Eye bolts in mild steel, Note: Requires MB suffix option listed above |
M16 Lifting Eye bolts in mild steel, Note: Requires MB suffix option listed above |
***Stainless steel lifting eye bolts also available, contact sales for information.
Product Reference* | Width (mm) | Height (MM) |
Depth (MM)
| Maximum Power Rating (W) | Maximum Voltage (kV) | Maximum Current (A) | Maximum Conductor Size (mm2) | Maximum Ways | Weight (kg) |
High Voltage |
IP66 to EN60529, Type 4X, DTS-01 |
>7Nm |
2mm 316L Stainless Steel (EN 1.4404) enclosure with orbital finish, silicone gasket and captive 316 stainless steel fasteners, 3mm 316L (EN 1.4404) Stainless Steel gland plates |
-20°C to +40°C or -50°C to +55°C (refer to certificate) |
3 conductors per phase in & 3 conductors per phase out |
Dependant upon configuration |
16mm2 to 1000mm2 |
Via studs on enclosure, door and gland plates |
Via 3mm thick external mounting straps, slotted upper strap for ease of installation Certification |
Enter your text here |
Zone 1 & 21, Gas and Dust / Class 1 Div 2 |
Ex eb (Increased Safety), Ex tb (Dust Protected) |
Ex eb IIC T4 Gb, Ex tb IIIC T70°C Db / Ex eb IIC T150°C Gb, Ex tb IIIC T110°C Db |
CML 16ATEX3324 & IECEx CML16.0100 / EAC: TC RU C-GB.MH04.B.00286 |
Enclosure Type |
Ingress Protection |
Impact Resistance |
Material
|
Ambient Temp Rating |
Maximum Terminations |
No. of Gland Plates |
Crimp lugs |
Earthing |
Mounting
|
Certification |
Area Classification |
Type of Protection |
Apparatus Coding
|
Certificate Number |
(x-x) demotes the number of connectors per phase 1st position = top, 2" position = bottom. For example: HVJB73(2-1) = 2 x conductors per phase top entry and 1 x conductor per phase bottom entry.
** Power rating is determined by ambient temp range: -20 to +40°C / -50 to +55°C respectively. A higher power rating can also be achieved if the enclosure is marked Ex e IIC T150°C Gb. —*For cables greater than 300mm2, it is advisable to use the HVJB8 size enclosure.
Arrangements Example